  • Monitors pH ranges between 32 and 122 degrees Fahrenheit.
  • Includes a 3.6-metre cable with a BNC terminal for direct board connection.
  • Compatible with both inline PVC piping and direct reservoir drop-in configurations.
  • 3-year warranty on all mechanical and electronic components
  • View More Details

Gagnez 293 points en faisant vos achats et obtenez $2.93 de réduction sur votre prochaine commande. Adhérez gratuitement au Club Récolte.

Des questions ? Parlez à un spécialiste. Mon–Fri, 9am–5pm PST
Livraison gratuite sur la plupart des articles Vers les 48 États continentaux
Tarification transparente Bénéficie d'une garantie d'alignement tarifaire
4.8/5 Rating 1938+ verified reviews
Paiement sécurisé Paiements sécurisés SSL

Send Us a Message

VOLUME PRICING

Achats commerciaux et en gros

Nous assistons les opérations et les installations agréées grâce à des tarifs dégressifs, des gestionnaires de compte dédiés et des consultations personnalisées sur l'équipement.

Commercial Inquiry

Contact Information
À TRAVERS LE REGARD DU CULTIVATEUR Évaluation pratique

À qui s'adresse cet article ?

  • You are adding real-time monitoring because manual testing is failing to catch nutrient drift between your daily checks.
  • You are integrating precise pH control because you need a system that logs data rather than relying on manual notes.

Ce que nous avons découvert

  • The 3.6-metre cable is generous, making it easy to reach your reservoir without needing to move the controller.
  • BNC connections provide a clean signal, but ensure you keep the probe cap wet or it will drift within a few days.

Ce que disent les utilisateurs

  • Users who installed this inline report that they saved hours of labour by not having to mix samples by hand.
  • Growers who set up remote alerts say they caught pH fluctuations early, saving them from potential nutrient lockout.

TrolMaster PPH-2 Inline & Reservoir pH Sensor

The TrolMaster PPH-2 is a dual-use pH probe that monitors nutrient solution pH either inline within an existing PVC piping system or as a drop-in in a reservoir — giving you more installation flexibility than a reservoir-only probe without requiring a full replumb. It connects directly to the AMP-2 sensor board via BNC terminal, feeding live pH readings to your TrolMaster controller for real-time monitoring. A 3.6-meter cable provides flexible positioning in either configuration, and the PPH-2's application range extends to aquariums and laboratories wherever accurate, ongoing pH tracking is needed.

For setups requiring installation into standard ¾" PVC tee fittings or AMP-3 sensor board compatibility, see the PPH-3.

Compatibility: TrolMaster Aqua-X NFS-1 (via AMP-2), Green-X (GCS-1 via AMP-2), and Tent-X (TCS-1 via AMP-2)

⚠️ pH probes must be stored with the protective storage cap in place and filled with the correct probe storage solution at all times. Allowing the probe tip to dry out completely will permanently damage the sensor element and void warranty coverage. Never store the PPH-2 dry or submerged in plain water.


What's Included

  • 1 × Inline pH Sensor (PPH-2)

Features

🧪
Inline & Reservoir pH Monitoring

Dual-use probe supports both inline PVC piping installation and reservoir drop-in use — monitor pH where it matters most without additional hardware.

🔌
BNC Direct Connection

BNC terminal connects directly to the AMP-2 sensor board — no additional adapters or converters required for a clean, secure signal path to the controller.

🌐
Wide Application Range

Suitable for hydroponics, aquariums, laboratories, and any environment requiring consistent pH monitoring. 3.6m cable for flexible placement in any setup.


TrolMaster PPH-2 Specifications

Specification Value
Measurement Parameter pH
Cable Length 3.6 meters (~12 ft)
Connector Type BNC
Installation Type Inline (PVC piping) or Drop-in reservoir
Compatible Sensor Board AMP-2
Working Environment Temperature 32–122°F (0–50°C), Humidity ≤90%
Package Dimensions 275mm (L) × 85mm (W) × 95mm (H)
Compatibility TrolMaster Aqua-X (via AMP-2), Green-X (via AMP-2), Tent-X (via AMP-2)

Support & Manuals

Warranty

TrolMaster backs the PPH-2 with a 3-year warranty from the original date of purchase, covering all mechanical and electronic components under normal operating conditions. Components that fail due to abnormal or improper usage are excluded from this coverage.

Important — pH probe storage requirement: pH probes must be stored with the protective storage cap in place and filled with the correct probe storage solution at all times. A probe that is allowed to dry out completely will permanently damage the sensor element and is explicitly excluded from warranty coverage. Any probe returned without the storage cap or in a dried-out state will not be eligible for a warranty claim.


FAQs

What does the PPH-2 measure?+

The PPH-2 measures the pH level of nutrient solution — either inline within a PVC piping system or submerged in a reservoir. When connected to an AMP-2 sensor board, the pH reading is passed to the TrolMaster controller and displayed on both the sensor board's LCD and the master controller screen simultaneously.

What is the difference between the PPH-1, PPH-2, and PPH-3?+

All three probes measure pH and connect via BNC terminal, but they differ in installation capability and sensor board support. The TrolMaster PPH-1 is a reservoir drop-in probe compatible with AMP-2 only. The PPH-2 adds inline PVC piping compatibility alongside reservoir drop-in use, also on AMP-2. The PPH-3 is a redesigned version with a reduced-diameter sleeve and threaded body for direct installation into standard ¾" PVC tee fittings, and is compatible with both AMP-2 and AMP-3 boards — making it the most versatile option for inline installations and AMP-3-based controller setups.

Which sensor boards and controllers is the PPH-2 compatible with?+

The PPH-2 is compatible with the AMP-2 sensor board, used with the TrolMaster Aqua-X NFS-1 controller. It connects via BNC terminal directly to the AMP-2 with no additional adapters. For setups using AMP-3-based controllers such as the Aqua-X NFS-2 or NFS-3 irrigation control system, the PPH-3 is the appropriate pH probe.

Can the PPH-2 be installed inline in a PVC piping system?+

Yes — the PPH-2 supports inline installation in PVC piping systems in addition to reservoir drop-in use. For installations specifically requiring a standard ¾" PVC tee fitting connection, the PPH-3 features a redesigned threaded body and reduced-diameter sleeve purpose-built for that fitting type. The PPH-2 is the practical choice when existing piping accommodates it and AMP-2 is the sensor board in use.

How should I store the PPH-2 when it's not in use?+

pH probes must always be stored with the protective storage cap in place and filled with the correct probe storage solution. Allowing the probe tip to dry out completely will permanently damage the sensor element and void warranty coverage. Never store the PPH-2 dry or submerged in plain water — only the designated probe storage solution maintains the sensor's integrity between uses.

Does the PPH-2 warranty cover probes that have dried out?+

No. Probes returned without the storage cap in place or in a dried-out condition are explicitly excluded from warranty coverage. pH probe longevity depends entirely on proper wet storage — this applies both between active measurements and during any period the probe is removed from the system.

Should I pair the PPH-2 with an EC/Temp probe?+

Yes — pH and EC together give you a complete picture of nutrient solution quality. The PPH-2 pairs directly with the TrolMaster PCT-1 (EC and temperature), both connecting to the same AMP-2 sensor board. This combination covers all three critical water quality parameters — pH, EC, and temperature — in a single monitoring setup without additional hardware.

Heureux de vous aider

Des questions sur ce produit ?

Nos spécialistes sont à votre écoute. Appelez-nous ou envoyez un message, et nous vous répondrons dans un délai d'un jour ouvrable (généralement en quelques heures).

Appelez le (778) 300-3154

Pourquoi Trimleaf

Au service des cultivateurs amateurs, des producteurs artisanaux et des entreprises commerciales de toute l'Amérique du Nord depuis 2016.

10+
Des années de connaissances spécialisées
4.8★
Plus de 1 900 avis vérifiés
50 000+
Exploitants agricoles desservis
120 et plus
Grandes marques d'équipement en stock