- 1 × Device Station (DST-2)
- 1 × 16ft RJ12 Cable
- 1 × 4ft RJ12 Cable
- 1 × RJ12 T-Splitter
TrolMaster DST-2 240V Temperature Device Station
- Supports 240V equipment up to 10 amps.
- Includes 16ft and 4ft RJ12 cables with T-splitter.
- LED indicator provides instant visual feedback on status.
- 3-year warranty on all mechanical and electronic components
- View More Details
Earn 147 points for shopping and get $1.47 off your next order. Join Harvest Club for free.
Commercial & Bulk Purchasing
We support operations & licensed facilities with volume pricing, dedicated account managers, and custom equipment consultation.
Who This Is For
- You are upgrading to 240V equipment because your current outlets cannot handle the power demands of your commercial heaters.
- You are centralizing your climate control system because managing high-voltage hardware with separate timers is becoming a complex labour burden.
What We Found
- We prefer the DST-2 for 240V setups because it bypasses the need for external contactors, keeping the wiring much cleaner.
- The one-button addressing works exactly as advertised, which saves a significant amount of time during initial configuration.
What Users Say
- Operators who switched to this station for their high-output heaters say they stopped tripping breakers during peak cold cycles.
- Facilities managers report that the visual status LED provides a quick way to confirm activity without needing to check the main controller.
TrolMaster DST-2 240V Temperature Device Station
Commercial-grade environmental management requires more than standard household power. High-capacity heaters and industrial cooling units often run on dedicated 240V circuits, which can leave standard control modules overwhelmed. The TrolMaster 240V DST-2 Environmental Control is the professional solution, engineered to bridge the gap between your TrolMaster Hydro-X HCS-1 and heavy-duty 240V equipment.
Unlike the standard DST-1 Temperature Station, the DST-2 is built specifically for 240V input, supporting devices up to 10 amps. This allows for seamless automation of high-voltage climate hardware without the need for complex wiring or external contactors. Setup is streamlined through the proven DS module process: simply connect via RJ12, press the addressing button, and allow your TrolMaster controller to take full command of your environment.
Compatibility: TrolMaster Hydro-X, Green-X, and Tent-X Systems
All DS-type modules support global plug types. Check the DS Modules Plug List (linked below) to confirm compatibility with your country's outlet standard before ordering.
What's Included
Features
240V Dedicated Input
Engineered for high-capacity 240V circuits to power commercial heaters and AC units.
LED Status Indicator
Color-coded LED provides instant visual feedback on connection, activity, and safety status.
One-Button Addressing
Quickly link to your controller with a single press or use the manual override toggle.
Plug & Play Setup
Includes all necessary RJ12 cables and splitters for immediate integration out of the box.
TrolMaster DST-2 Specifications
| Specification | Value |
|---|---|
| Input Voltage | 240 VAC, 50/60 Hz |
| Output Voltage | 240 VAC, 50/60 Hz |
| Output Current | 10A |
| Working Environment | Temperature 32–122°F (0–50°C), Humidity ≤90% |
| Package Dimensions | 85mm (L) × 80mm (W) × 90mm (H) |
| Gross Weight | 0.34 kg |
| Compatibility | TrolMaster Hydro-X, Green-X, Tent-X |
Support & Manuals
Warranty
TrolMaster backs the DST-2 with a 3-year warranty from the original date of purchase, covering all mechanical and electronic components under normal operating conditions. Components that fail due to abnormal or improper usage are excluded from this coverage.
FAQs
The primary difference is the voltage requirement. While the DST-1 handles a wide range of 100-240V, the DST-2 is specifically optimized for dedicated 240V circuits commonly used by commercial heating and cooling units. Both support a 10A output.
You can control any heating or cooling device that operates on 240 VAC and draws a maximum of 10 amps, such as large space heaters or portable air conditioning units.
- Fast blinking green: Not addressed or connection lost.
- Slow blinking green: Connected and addressed (Device OFF).
- Solid green: Connected and addressed (Device ON).
- Blinking red: Overload detected. Unplug to reset.
Yes. By pressing and holding the button on the DST-2 module, you can manually toggle the connected device on or off independently of the controller's current programming.
Connect the DST-2 using the included RJ12 cables to your Hydro-X controller. Press the button on the module once to address it; the LED will change from fast to slow blinking green to confirm the link.
Questions About This Product?
Our specialists are happy to help. Call us or send a message and we'll get back to you within one business day (most of the time within a few hours.)
Why Trimleaf
Equipping home growers, craft producers, and commercial operations across North America since 2016.