Skip to main content

Send Us a Message

Search

TrolMaster DST-1 110V Temperature Device Station

starting from 0% interest financing from /mo.

Payment Options

Options:Pay in Four, Pay Monthly
Amount:Up to $1,500 (Pay in 4)
Up to $10,000 (Monthly)
Schedule:Bi-weekly to Monthly
Term:6 weeks, 12 or 24 months
Interest:0% to 35.99% APR*
Credit Check?Soft Check Only
Schedule:Bi-weekly to Monthly
Term:6 weeks, 6 or 12 months
Interest:0% to 35.99% APR*
Credit Check?Soft Check Only
Finance up to:$4,000
Options:Pay in 6, Pay Monthly
Amount:Up to $1,500 (Pay in 6)
$1,501–$30,000 (Monthly)
Schedule:Bi-weekly / Monthly
Term:6 bi-weekly / 6–60 months
Interest:0% (up to $1,500) / 11.99% APR
Not available in:Quebec
  • Supports 100 to 240 VAC input with up to 10 amps for global climate equipment compatibility.
  • Features plug and play connectivity with included RJ12 cables for a tool-free installation.
  • Works directly with Hydro-X, Green-X, and Tent-X control systems.
  • 3-year warranty on all mechanical and electronic components
  • View More Details

Earn 110 points for shopping and get $1.10 off your next order. Join Harvest Club for free.

Questions? Talk to a specialist. Mon–Fri, 9am–5pm PST
Free Shipping On Most Items To the Provinces*
Transparent Pricing Backed w/ price match guarantee
Secure Checkout SSL encrypted payments

Send Us a Message

Ask Sage about this product
VOLUME PRICING

Commercial & Bulk Purchasing

We support operations & licensed facilities with volume pricing, dedicated account managers, and custom equipment consultation.

Commercial Inquiry

Contact Information
THROUGH THE Cultivator's LENS Hands-On Evaluation

  • You are adding climate modules to your controller because your current hardware requires manual switching and manual oversight.
  • You are bridging your standard heating and cooling gear into the controller network because you want to stop juggling multiple incompatible electrical adapters.

  • The one-button link is a massive time-saver when you are setting up or reconfiguring your climate zones.
  • The status LED is bright enough to see from across the room, which makes checking if a heater is active painless.

  • Users report that integrating their space heaters into the system stopped the temperature swings they dealt with during the night.
  • Growers who set these up say they stopped worrying about manual adjustments because the controller handles their climate equipment reliably.

TrolMaster DST-1 110V Temperature Device Station

Maintaining the perfect environment in your grow room shouldn't be a constant battle with manual switches and incompatible hardware. The TrolMaster DST-1 Temperature Device Station is the essential bridge that integrates any standard heating or cooling unit directly into your environmental control system. Organize your control setup professionally by housing your main unit in a TrolMaster SCC-4 Mini Controller Cabinet. By providing your controller with full on/off command over climate equipment, the DST-1 ensures your plants stay within their optimal temperature range without the need for complex wiring or expensive electrical work.

This versatile module is designed for universal compatibility, accepting devices running on global voltage standards (100–240 VAC) at up to 10 amps. Whether you are using the TrolMaster Hydro-X HCS-1 or a specialized tent setup, the DST-1 offers a plug-and-play solution. Growers needing specific cooling-only logic may also consider the TrolMaster Hydro-X TS-1 Cool-Only Thermostat Station. For those running high-power equipment, you might also consider the TrolMaster DST-2 240V Temperature Device Station for dedicated high-voltage temperature management. While the DST-1 handles heat, you can also manage moisture levels with the TrolMaster DSH-1 110V Humidity Device Station.

Compatibility: TrolMaster Hydro-X, Green-X, and Tent-X Systems

All DS-type modules support global plug types. Check the DS Modules Plug List (linked below) to confirm compatibility with your country's outlet standard before ordering.


What's Included

  • 1 × Device Station (DST-1)
  • 1 × 16ft RJ12 Cable
  • 1 × 4ft RJ12 Cable
  • 1 × RJ12 T-Splitter

Features

🌡️
Universal Voltage

Supports 100–240 VAC at 10A, making it compatible with heating and cooling devices worldwide.

💡
LED Status

Color-coded LED indicator shows connection, activity, and overload status at a glance.

📍
Easy Addressing

One-button linking for instant connection to your controller with manual override capabilities.

🔌
Plug & Play

Includes all necessary RJ12 cables and splitters for a tool-free setup in minutes.


TrolMaster DST-1 Specifications

Specification Value
Input Voltage 100–240 VAC, 50/60 Hz
Output Voltage 100–240 VAC, 50/60 Hz
Output Current 10A
Working Environment Temperature 32–122°F (0–50°C), Humidity ≤90%
Package Dimensions 85mm (L) × 80mm (W) × 90mm (H)
Gross Weight 0.34 kg
Compatibility TrolMaster Hydro-X, Green-X, Tent-X

Warranty

TrolMaster backs the DST-1 with a 3-year warranty from the original date of purchase, covering all mechanical and electronic components under normal operating conditions. Components that fail due to abnormal or improper usage are excluded from this coverage.


FAQs

What devices can I control with the DST-1?+

The DST-1 can control any standard heating or cooling device that runs on 100–240 VAC and draws no more than 10 amps. If you are using a mini-split AC instead of a standard cooling unit, the TrolMaster ARS-1 Mini-Split AC IR Remote Station is the specialized tool for that job.

What do the different LED colors mean?+
  • Fast blinking green: Module is not addressed or connection is lost.
  • Slow blinking green: Module is connected and the device is currently OFF.
  • Solid green: Module is connected and the device is currently ON.
  • Blinking red: Overload detected. Unplug to reset.
How do I link the DST-1 to my controller?+

After connecting via RJ12 cable, press the button on the module once. The LED will change from fast blinking to slow blinking green to indicate a successful link.

Can I manually override the station?+

Yes. Press and hold the button on the DST-1 to manually toggle the connected device on or off independently of the controller's current program.

What happens if the station is overloaded?+

If the device draws more than 10A, the LED will blink red and trigger protection. Unplug the unit to reset it and ensure your device is within the 10A limit before reconnecting. For comprehensive room management, this station pairs perfectly with the TrolMaster DSC-1 CO2 Device Station to regulate carbon dioxide levels, and for safety, you can add a TrolMaster TSS-1 Touch Spot Leak Sensor Set to detect potential floods.

Happy To Help

Questions About This Product?

Our specialists are happy to help. Call us or send a message and we'll get back to you within one business day (most of the time within a few hours.)

Call (778) 300-3154

Why Trimleaf

Equipping home growers, craft producers, and commercial operations across North America since 2016.

10+
Years of Specialist Knowledge
4.8★
1957+ Verified Reviews
50,000+
Growers Served
120+
Top Equipment Brands in Stock